<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22276</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: WARNING: Slipsheet roller sensors fault, machine will be slower
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Probably swapped. Machines running &lt;1.16 will be slower.
Machines running 1.20 will not work if the new compactor
is installed.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resuem if possible, otherwise call Creo Response Center.
</text></DescriptionText>
</OperatorAction>
<Cause>
Slipsheet roller sensor did not indicate closed before the roller
were opened, or did not indicate open before the rollers were closed.
This suggests that the sensors are reversed or one is not functioning.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/val_cal_nci.xml</LinkAddress><LinkTitle>NVS: val nci</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:02 2008 PST
</Updated>
<Links>
</Links>
</Error>